04 / LC Series · Liquid-Cooled

Liquid-Cooled
Load Banks

Megawatts in a fraction of the footprint. LC-Series liquid-cooled load banks reject heat to facility water rather than to air — enabling very high power density, near-silent operation and indoor MW-class testing where air-cooled units simply will not fit.

Capacity
≤ 6 MW
Coolant
Water / glycol
Noise
< 65 dB(A)
Voltage
≤ 690 V
Liquid-cooled load bank — LC Series unit

Overview

Heat to water,
not to the room.

Air-cooled load banks reject their heat — and their noise — straight into the surrounding space. At megawatt scale that becomes impractical indoors. Liquid cooling transfers the load energy into a water or water-glycol circuit, so a far higher power density fits into a compact, quiet enclosure that can run inside a data hall or plant room.

The LC-Series couples to facility chilled or condenser water, or to a packaged heat-rejection skid, with instrumented flow, temperature and pressure monitoring. It is the natural choice for sustained high-capacity testing and for heat-reuse and CDU validation in modern data-centre builds.

Heat Rejection
Facility water / glycol or packaged skid
Power Density
MW-class capacity in a compact footprint
Acoustics
Low-noise operation, suitable for occupied buildings
Monitoring
Flow, supply/return temperature, pressure, leak detection
Formats
Cabinet · skid · containerised

Product range

LC Series
ratings.

A representative selection of the standard LC-Series range. Flow figures are approximate and depend on supply temperature; ratings and formats are engineered to order.

Model Capacity Voltage Coolant Flow (approx.) Format
LC-500500 kW400–690 VWater/glycol30 m³/hCabinet
LC-10001 MW400–690 VWater/glycol60 m³/hCabinet
LC-20002 MW400–690 VWater/glycol120 m³/hSkid
LC-30003 MW400–690 VWater/glycol175 m³/hSkid
LC-45004.5 MW400–690 VWater/glycol260 m³/hContainerised
LC-60006 MW400–690 VWater/glycol345 m³/hContainerised

Representative range — figures configurable to order.

Engineering

Built into every unit.

01

High Power Density

MW-class capacity in minimal floor area.

02

Low Noise

Quiet enough to operate inside occupied buildings.

03

Facility Water Coupling

Chilled or condenser water, or a packaged skid.

04

Instrumented Cooling

Flow, temperature, pressure and leak detection.

05

Heat-Reuse Ready

Supports heat-recovery and CDU validation testing.

06

Continuous Duty

Engineered for sustained full-load operation.

Applications

Where LC-Series
earns its place.

Wherever high capacity, low noise and a small footprint must coexist indoors.

Data Centre Commissioning Heat-Reuse Validation CDU Testing Power Generation Marine Indoor MW Testing District Heating Research Facilities Grid / BESS Rental Fleets

Specify your
LC-Series unit.

Tell us the capacity, the available cooling water and the space you have, and we will return a full specification and quotation — typically within one working day.