04 / LC Series · Liquid-Cooled
Liquid-Cooled
Load Banks
Megawatts in a fraction of the footprint. LC-Series liquid-cooled load banks reject heat to facility water rather than to air — enabling very high power density, near-silent operation and indoor MW-class testing where air-cooled units simply will not fit.
Overview
Heat to water,
not to the room.
Air-cooled load banks reject their heat — and their noise — straight into the surrounding space. At megawatt scale that becomes impractical indoors. Liquid cooling transfers the load energy into a water or water-glycol circuit, so a far higher power density fits into a compact, quiet enclosure that can run inside a data hall or plant room.
The LC-Series couples to facility chilled or condenser water, or to a packaged heat-rejection skid, with instrumented flow, temperature and pressure monitoring. It is the natural choice for sustained high-capacity testing and for heat-reuse and CDU validation in modern data-centre builds.
- Heat Rejection
- Facility water / glycol or packaged skid
- Power Density
- MW-class capacity in a compact footprint
- Acoustics
- Low-noise operation, suitable for occupied buildings
- Monitoring
- Flow, supply/return temperature, pressure, leak detection
- Formats
- Cabinet · skid · containerised
Product range
LC Series
ratings.
A representative selection of the standard LC-Series range. Flow figures are approximate and depend on supply temperature; ratings and formats are engineered to order.
| Model | Capacity | Voltage | Coolant | Flow (approx.) | Format |
|---|---|---|---|---|---|
| LC-500 | 500 kW | 400–690 V | Water/glycol | 30 m³/h | Cabinet |
| LC-1000 | 1 MW | 400–690 V | Water/glycol | 60 m³/h | Cabinet |
| LC-2000 | 2 MW | 400–690 V | Water/glycol | 120 m³/h | Skid |
| LC-3000 | 3 MW | 400–690 V | Water/glycol | 175 m³/h | Skid |
| LC-4500 | 4.5 MW | 400–690 V | Water/glycol | 260 m³/h | Containerised |
| LC-6000 | 6 MW | 400–690 V | Water/glycol | 345 m³/h | Containerised |
Representative range — figures configurable to order.
Engineering
Built into every unit.
High Power Density
MW-class capacity in minimal floor area.
Low Noise
Quiet enough to operate inside occupied buildings.
Facility Water Coupling
Chilled or condenser water, or a packaged skid.
Instrumented Cooling
Flow, temperature, pressure and leak detection.
Heat-Reuse Ready
Supports heat-recovery and CDU validation testing.
Continuous Duty
Engineered for sustained full-load operation.
Applications
Where LC-Series
earns its place.
Wherever high capacity, low noise and a small footprint must coexist indoors.
Continue the range
Related families.
Specify your
LC-Series unit.
Tell us the capacity, the available cooling water and the space you have, and we will return a full specification and quotation — typically within one working day.